Smoke Evacuation System

IKEDA Smoke Evacuation System: Efficiently Purify Surgical Smoke, Safeguarding Healthcare Professionals

Jun 23 , 2026

With the continuous advancement of modern medical technology, devices such as laser scalpels, electrosurgical units, and ultrasonic scalpels are widely used in surgical procedures. However, the surgical smoke generated during operations poses serious health risks to operating room personnel. Surgical smoke not only obstructs the vision of surgical teams, affecting precise localization of surgical sites, but also releases toxic and hazardous substances into the surrounding air. These substances can irritate the nasopharynx and eyes of medical staff and anesthesiologists, even causing nausea, while posing long-term health hazards. Conventional surgical masks fail to effectively block smoke particles. Therefore, equipping operating rooms with high-efficiency surgical smoke filtration systems is essential.

The IKEDA AKX-9690 Smoke Evacuation System is designed for multistage absorption and filtration of smoke generated during surgeries. It effectively eliminates harmful smoke produced by procedures such as gynecological LEEP, high-frequency electrosurgery, microwave therapy, and CO₂ laser surgeries. By purifying the ambient air, it reduces the exposure of healthcare professionals and patients to hazardous smoke.

Smoke Evacuation System

Advantages of the Smoke Evacuation System
1. Four-stage multi-layer filtration system for high-efficiency purification

The AKX-9690 Smoke Evacuation System uses advanced ULPA filtration technology to effectively capture and filter 99.999% of surgical smoke, eliminating odors, particles, and other potentially hazardous substances, combating harmful substances in the operating room air and protecting the health of doctors.

Smoke Evacuation System

2. Three start-up modes for flexible adaptation to clinical habits

Supports manual start, remote foot switch, and device linkage control. Doctors can choose freely according to the surgical procedure without interrupting operation.

3. Intelligent detection, filter life up to 35 hours

The intelligent filter detection function promptly reminds you to replace the external filter. The screen displays the filter depletion status in real time.

4. 7-inch Smart Touchscreen for Convenient Operation
Equipped with a 7-inch LCD touchscreen, the interface is clear and intuitive, making parameter adjustment and status monitoring easy and improving clinical operation efficiency.

5. Closed-Loop Valve Design for Zero-Leakage Pneumoperitoneum Pressure
Addressing the special needs of minimally invasive endoscopic surgery, a closed-loop valve function is added to ensure stable pneumoperitoneum pressure, eliminate gas leakage during the smoke purification process, and ensure the safety of laparoscopic surgery.

Smoke Evacuation System

Main Application Scenarios of the Smoke Evacuation System

1. Surgical Operating Room
Suitable for open surgery, laparoscopic surgery, and other scenarios, it can efficiently purify surgical fumes and harmful particles generated by energy devices such as high-frequency electrosurgical units, ultrasonic scalpels, laser scalpels, and LEEP (Loop Electrosurgical Excision Procedures).

2. Medical Aesthetics Department
It can handle suspended particles, odors, and harmful fumes generated during laser treatment, radiofrequency ablation, and other procedures.

3. Minimally Invasive Gynecology/Urology Clinic
Adapted to day surgery scenarios such as LEEP cervical conization and laser resection of bladder tumors, it precisely purifies harmful fumes generated during minimally invasive procedures.

Smoke Evacuation System

Surgical smoke is a significant occupational risk in clinical practice, and ordinary protective measures are insufficient to fully mitigate its multiple harmful effects. The IKEDA AKX-9690 Smoke Evacuation System, with its high-performance ULPA filtration capabilities, combined with practical functions such as intelligent touch control, multiple start modes, filter monitoring, and a closed-loop valve, balances purification effectiveness with ease of clinical operation. It can be used in various scenarios including surgery, aesthetic medicine, and minimally invasive gynecological and urological clinics, effectively removing harmful smoke particles and odors during surgery, truly protecting the safety of medical staff and patients. It is a reliable device for dealing with the hazards of surgical smoke in the operating room.

Related News
[2026-10-13] IKEDA to Exhibit at CMEF 2026 in Beijing: Showcasing a Full Spectrum of Endoscopic Imaging Innovations [2025-11-25] A Decade at MEDICA: IKEDA Endoscopic Innovations for a Healthier Future [2025-10-22] IKEDA to Showcase Cutting-Edge Endoscope Solutions at MEDICA 2025 [2024-05-17] Gallbladder Removal: A Step-by-Step Guide to Avoiding Pitfalls